-- CISCO-OPTICAL-MONITOR-MIB.my
--   
-- May 2002, Sonal Maheshwari, Mickey Spiegel
--   
-- Copyright (c) 2002,-2007 by Cisco Systems, Inc.
--   
-- All rights reserved.
-- ****************************************************************

CISCO-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Integer32,
    Unsigned32,
    MODULE-IDENTITY,
    NOTIFICATION-TYPE,
    OBJECT-TYPE
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    NOTIFICATION-GROUP,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    TEXTUAL-CONVENTION,
    TimeStamp
        FROM SNMPv2-TC
    ifIndex
        FROM IF-MIB
    ciscoMgmt
        FROM CISCO-SMI;


ciscoOpticalMonitorMIB MODULE-IDENTITY
    LAST-UPDATED    "200701020000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: 170 W Tasman Drive
            San Jose, CA 95134

            Tel: +1 800 553-NETS

            E-mail: cs-dwdm@cisco.com"
    DESCRIPTION
        "This MIB module defines objects to monitor optical
        characteristics and set corresponding thresholds on the
        optical interfaces in a network element.
        "
    REVISION        "200701020000Z"
    DESCRIPTION
        "Add cOpticalMonIfTimeGroup,
        cOpticalMIBEnableConfigGroup,
        cOpticalMIBIntervalConfigGroup,
        cOpticalMonThreshSourceGroup."
    REVISION        "200205100000Z"
    DESCRIPTION
        "The initial revision of this MIB."
          ::= { ciscoMgmt 264 }


-- Textual Conventions

OpticalParameterType ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "This value indicates the optical parameter that is
        being monitored. Valid values are -

        power (1)          : Optical Power (AC + DC) in 1/10ths of dBm
        acPower (2)        : Optical AC Power in 1/10ths of dBm
        ambientTemp (3)    : Ambient Temperature in 1/10ths of degrees
                             centigrade
        laserTemp (4)      : Laser Temperature in 1/10ths of degrees
                             centigrade
        biasCurrent (5)    : Laser bias current in 100s of microamperes
        peltierCurrent (6) : Laser peltier current in milliamperes
        xcvrVoltage (7)    : Transceiver voltage in millivolts
        "
    SYNTAX          INTEGER  {
                        power(1),
                        acPower(2),
                        ambientTemp(3),
                        laserTemp(4),
                        biasCurrent(5),
                        peltierCurrent(6),
                        xcvrVoltage(7)
                    }

OpticalParameterValue ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The value of the optical parameter that is being monitored.

        The range of values varies depending on the type of optical
        parameter being monitored, as identified by a corresponding
        object with syntax OpticalParameterType.

        When the optical parameter being monitored is 'power' or
        'acPower', the supported range is from -400 to 250, in
        1/10ths of dBm.
        Example: A value of -300 represents a power level of -30.0 dBm.

        When the optical parameter being monitored is 'laserTemp' or
        'ambientTemp', the supported range is from -500 to 850, in
        1/10ths of degrees centigrade.
        Example: A value of 235 represents a temperature reading of
        23.5 degrees C.

        When the optical parameter being monitored is 'biasCurrent',
        the supported range is from 0 to 10000, in 100s of
        microamperes.
        Example: A value of 500 represents a bias current reading of
        50,000 microamperes.

        When the optical parameter being monitored is 'peltierCurrent',
        the supported range is from -10000 to 10000, in milliamperes.

        When the optical parameter being monitored is 'xcvrVoltage',
        the supported range is from 0 to 10000, in millivolts.

        The distinguished value of '-1000000' indicates that the object
        has not yet been initialized or does not apply.
        "
    SYNTAX          Integer32 (-1000000..1000000 )

OpticalIfDirection ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "This value indicates the direction being monitored at
        the optical interface.
        "
    SYNTAX          INTEGER  {
                        receive(1),
                        transmit(2),
                        notApplicable(3)
                    }

OpticalIfMonLocation ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "This value applies when there are multiple points
        at which optical characteristics can be measured, in the
        given direction, at an interface. It indicates whether the
        optical characteristics are measured before or after
        adjustment (e.g. optical amplification or attenuation).

        The codepoint 'notApplicable' should be used if no
        amplifier/attenuator exists at an interface.
        "
    SYNTAX          INTEGER  {
                        beforeAdjustment(1),
                        afterAdjustment(2),
                        notApplicable(3)
                    }

OpticalAlarmStatus ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "A bitmap that indicates the current status of thresholds
        on an interface. The bit is set to 1 if the threshold is
        currently being exceeded on the interface and will be set to 0
        otherwise.

        (MSB)                (LSB)
          7  6  5  4  3  2  1  0
         +----------------------+
         |                      |
         +----------------------+
                      |  |  |  |
                      |  |  |  +-- High alarm threshold
                      |  |  +----- High warning threshold
                      |  +-------- Low alarm threshold
                      +----------- Low warning threshold

        To minimize the probability of prematurely reacting to
        momentary signal variations, a soak time may be incorporated
        into the status indications in the following manner.
        The indication is set when the threshold violation persists
        for a period of time that exceeds the set soak interval.
        The indication is cleared  when no threshold violation occurs
        for a period of time which exceeds the clear soak interval.
        In GR-2918-CORE, the recommended set soak interval is 2.5
        seconds (plus/minus 0.5 seconds), and the recommended clear
        soak interval is 10 seconds (plus/minus 0.5 seconds).
        "

    REFERENCE
        "Telcordia Technologies Generic Requirements
        GR-2918-CORE, Issue 4, December 1999, Section 8.11"
    SYNTAX          OCTET STRING (SIZE (1))

OpticalAlarmSeverity ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The severity of a trouble condition. A smaller enumerated
        integer value indicates that the condition is more severe.

        The severities are defined as follows:

        'critical'    An alarm used to indicate a severe,
                      service-affecting condition has occurred and that
                      immediate corrective action is imperative,
                      regardless of the time of day or day of the week.

        'major'       An alarm used for hardware or software conditions
                      that indicate a serious disruption of service or
                      malfunctioning or failure of important hardware.
                      These troubles require the immediate attention and
                      response of a technician to restore or maintain
                      system capability. The urgency is less than in
                      critical situations because of a lesser immediate
                      or impending effect on service or system
                      performance.

        'minor'       An alarm used for troubles that do not have a
                      serious effect on service to customers or for
                      troubles in hardware that are not essential to
                      the operation of the system.

        'notAlarmed'  An event used for troubles that do not require
                      action, for troubles that are reported as a
                      result of manually initiated diagnostics, or for
                      transient events such as crossing warning
                      thresholds.  This event can also be used to
                      raise attention to a condition that could
                      possibly be an impending problem.

        'notReported' An event used for troubles similar to those
                      described under 'notAlarmed', and that
                      do not cause notifications to be generated. The
                      information for these events is retrievable from
                      the network element.

        'cleared'     This value indicates that a previously
                      occuring alarm condition has been cleared, or
                      that no trouble condition is present.

        "

    REFERENCE
        "Telcordia Technologies Generic Requirements
        GR-474-CORE, Issue 1, December 1997, Section 2.2"
    SYNTAX          INTEGER  {
                        critical(1),
                        major(2),
                        minor(3),
                        notAlarmed(4),
                        notReported(5),
                        cleared(6)
                    }

OpticalAlarmSeverityOrZero ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "A value of either '0' or a valid optical alarm severity."
    SYNTAX          INTEGER (0..6)

OpticalPMPeriod ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "This value indicates the time period over which performance
        monitoring data has been collected."
    SYNTAX          INTEGER  {
                        fifteenMin(1),
                        twentyFourHour(2)
                    }
-- MIB Object Definitions
cOpticalMonitorMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoOpticalMonitorMIB 1 }

-- groups in this MIB module
cOpticalMonGroup  OBJECT IDENTIFIER
    ::= { cOpticalMonitorMIBObjects 1 }

cOpticalPMGroup  OBJECT IDENTIFIER
    ::= { cOpticalMonitorMIBObjects 2 }

-- cOpticalMonTable

cOpticalMonTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF COpticalMonEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table provides objects to monitor optical
        parameters in a network element. It also provides
        objects for setting high and low threshold levels, with
        configurable severities, on these monitored parameters."
    ::= { cOpticalMonGroup 1 }

cOpticalMonEntry OBJECT-TYPE
    SYNTAX          COpticalMonEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry in the cOpticalMonTable provides objects to
        monitor an optical parameter and set threshold levels
        on that parameter, at an optical interface.

        Note that the set of monitored optical parameters may vary
        based on interface type, direction, and monitoring location.

        Examples of interfaces that can have an entry in this table
        include optical transceivers, interfaces before and after
        optical amplifiers, and interfaces before and after optical
        attenuators."
    INDEX           {
                        ifIndex,
                        cOpticalMonDirection,
                        cOpticalMonLocation,
                        cOpticalMonParameterType
                    } 
    ::= { cOpticalMonTable 1 }

COpticalMonEntry ::= SEQUENCE {
        cOpticalMonDirection           OpticalIfDirection,
        cOpticalMonLocation            OpticalIfMonLocation,
        cOpticalMonParameterType       OpticalParameterType,
        cOpticalParameterValue         OpticalParameterValue,
        cOpticalParamHighAlarmThresh   OpticalParameterValue,
        cOpticalParamHighAlarmSev      OpticalAlarmSeverity,
        cOpticalParamHighWarningThresh OpticalParameterValue,
        cOpticalParamHighWarningSev    OpticalAlarmSeverity,
        cOpticalParamLowAlarmThresh    OpticalParameterValue,
        cOpticalParamLowAlarmSev       OpticalAlarmSeverity,
        cOpticalParamLowWarningThresh  OpticalParameterValue,
        cOpticalParamLowWarningSev     OpticalAlarmSeverity,
        cOpticalParamAlarmStatus       OpticalAlarmStatus,
        cOpticalParamAlarmCurMaxThresh OpticalParameterValue,
        cOpticalParamAlarmCurMaxSev    OpticalAlarmSeverity,
        cOpticalParamAlarmLastChange   TimeStamp,
        cOpticalMon15MinValidIntervals Unsigned32,
        cOpticalMon24HrValidIntervals  Unsigned32,
        cOpticalParamThreshSource      BITS
}

cOpticalMonDirection OBJECT-TYPE
    SYNTAX          OpticalIfDirection
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the direction monitored for the
        optical interface, in this entry." 
    ::= { cOpticalMonEntry 1 }

cOpticalMonLocation OBJECT-TYPE
    SYNTAX          OpticalIfMonLocation
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates whether the optical characteristics are
        measured before or after adjustment (e.g. optical amplification
        or attenuation), at this interface." 
    ::= { cOpticalMonEntry 2 }

cOpticalMonParameterType OBJECT-TYPE
    SYNTAX          OpticalParameterType
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored in this entry." 
    ::= { cOpticalMonEntry 3 }

cOpticalParameterValue OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the value measured for the particular
        optical parameter specified by the cOpticalMonParameterType
        object." 
    ::= { cOpticalMonEntry 4 }

cOpticalParamHighAlarmThresh OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to set a high alarm threshold on the
        optical parameter being monitored.

        An alarm condition will be raised if the value given by
        cOpticalParameterValue goes from below the value configured in
        this object to above the value configured in this object, or if
        the initial value of cOpticalParameterValue exceeds the value
        configured in this object. For network elements that
        incorporate a soak time in the status indications, this alarm
        will be indicated in the cOpticalParamAlarmStatus object only
        after it persists for a period of time that equals the set soak
        interval.

        The severity level of the alarm is specified by the
        cOpticalParamHighAlarmSev object.

        When the cOpticalMonParameterType object is set to 'power'
        for the receive direction at a transceiver, this object
        specifies the receiver saturation level." 
    ::= { cOpticalMonEntry 5 }

cOpticalParamHighAlarmSev OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverity
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to specify a severity level associated
        with the high alarm threshold given by the
        cOpticalParamHighAlarmThresh object. The values 'notAlarmed',
        'notReported', and 'cleared' do not apply.

        The severity level configured in this object must be higher
        than the level configured in the cOpticalParamHighWarningSev
        object." 
    ::= { cOpticalMonEntry 6 }

cOpticalParamHighWarningThresh OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to set a high warning threshold on
        the optical parameter being monitored.

        A threshold crossing condition will be indicated if the value
        given by cOpticalParameterValue goes from below the value
        configured in this object to above the value configured in this
        object, or if the initial value of cOpticalParameterValue
        exceeds the value configured in this object. For network
        elements that incorporate a soak time in the status
        indications, this threshold violation will be indicated in the
        cOpticalParamAlarmStatus object only after it persists for
        a period of time that equals the set soak interval.

        This threshold crossing may or may not be alarmed or
        reported, based on the severity level specified by the
        cOpticalParamHighWarningSev object." 
    ::= { cOpticalMonEntry 7 }

cOpticalParamHighWarningSev OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverity
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to specify a severity level associated
        with the high warning threshold given by the
        cOpticalParamHighWarningThresh object. The values 'critical',
        'major', and 'cleared' do not apply.

        The severity level configured in this object must be lower
        than the level configured in the cOpticalParamHighAlarmSev
        object.

        If this object is set to 'notReported', no notifications will
        be generated when this threshold is exceeded, irrespective
        of the value configured in the cOpticalNotifyEnable object." 
    ::= { cOpticalMonEntry 8 }

cOpticalParamLowAlarmThresh OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to set a low alarm threshold on the
        optical parameter being monitored.

        An alarm condition will be raised if the value given by
        cOpticalParameterValue goes from above the value configured in
        this object to below the value configured in this object, or if
        the initial value of cOpticalParameterValue is lower than the
        value configured in this object. For network elements that
        incorporate a soak time in the status indications, this alarm
        will be indicated in the cOpticalParamAlarmStatus object only
        after it persists for a period of time that equals the set soak
        interval.

        The severity level of this alarm is specified by the
        cOpticalParamLowAlarmSev object.

        When the cOpticalMonParameterType object is set to 'power'
        for the receive direction and when the interface supports
        alarms based on loss of light, this object specifies the
        optical power threshold for declaring loss of light. Also,
        when optical amplifiers are present in the network, in the
        receive direction, this value may need to be configured,
        since the noise floor may be higher than the minimum
        sensitivity of the receiver." 
    ::= { cOpticalMonEntry 9 }

cOpticalParamLowAlarmSev OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverity
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to specify a severity level associated
        with the low alarm threshold given by the
        cOpticalParamLowAlarmThresh object. The values 'notAlarmed',
        'notReported', and 'cleared' do not apply.

        The severity level configured in this object must be higher
        than the level configured in the cOpticalParamLowWarningSev
        object." 
    ::= { cOpticalMonEntry 10 }

cOpticalParamLowWarningThresh OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to set a low warning threshold on
        the optical parameter being monitored.

        A threshold crossing condition will be indicated if the value
        given by cOpticalParameterValue goes from above the value
        configured in this object to below the value configured in this
        object, or if the initial value of cOpticalParameterValue
        object is lower than the value configured in this object. For
        network elements that incorporate a soak time in the status
        indications, this threshold violation will be indicated in the
        cOpticalParamAlarmStatus object only after it persists for
        a period of time that equals the set soak interval.

        This threshold crossing may or may not be alarmed or
        reported, based on the severity level specified by the
        cOpticalParamLowWarningSev object." 
    ::= { cOpticalMonEntry 11 }

cOpticalParamLowWarningSev OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverity
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object is used to specify a severity level associated
        with the low warning threshold given by the
        cOpticalParamLowWarningThresh object. The values 'critical',
        'major', and 'cleared' do not apply.

        The severity level configured in this object must be lower
        than the level configured in the cOpticalParamLowAlarmSev
        object.

        If this object is set to 'notReported', no notifications will
        be generated when this threshold is exceeded, irrespective
        of the value configured in the cOpticalNotifyEnable object." 
    ::= { cOpticalMonEntry 12 }

cOpticalParamAlarmStatus OBJECT-TYPE
    SYNTAX          OpticalAlarmStatus
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object is used to indicate the current status of
        the thresholds for the monitored optical parameter
        on the interface.

        If a threshold is currently being exceeded on the
        interface, the corresponding bit in this object will be set
        to 1. Otherwise, the bit will be set to 0." 
    ::= { cOpticalMonEntry 13 }

cOpticalParamAlarmCurMaxThresh OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the threshold value of the highest
        severity threshold that is currently being exceeded
        on the interface, for the optical parameter.
        If no threshold value is currently being
        exceeded, then the value '-1000000' is returned." 
    ::= { cOpticalMonEntry 14 }

cOpticalParamAlarmCurMaxSev OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverity
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the maximum severity of any thresholds
        that are currently being exceeded on the interface, for the
        optical parameter." 
    ::= { cOpticalMonEntry 15 }

cOpticalParamAlarmLastChange OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the value of sysUpTime at the last time
        a threshold related to a particular optical parameter was
        exceeded or cleared on the interface." 
    ::= { cOpticalMonEntry 16 }

cOpticalMon15MinValidIntervals OBJECT-TYPE
    SYNTAX          Unsigned32 (0..96 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the number of previous 15 minute
        intervals for which valid performance monitoring data
        has been stored on the interface.

        The value of this object will be n (where n is the maximum
        number of 15 minute intervals supported at this interface),
        unless the measurement was (re-)started within the last
        (nx15) minutes, in which case the value will be the
        number of previous 15 minute intervals for which the agent
        has some data." 
    ::= { cOpticalMonEntry 17 }

cOpticalMon24HrValidIntervals OBJECT-TYPE
    SYNTAX          Unsigned32 (0..1 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the number of previous 24 hour
        intervals for which valid performance monitoring data
        has been stored on the interface.

        The value of this object will be 0 if the measurement
        was (re-)started within the last 24 hours, or 1 otherwise." 
    ::= { cOpticalMonEntry 18 }

cOpticalParamThreshSource OBJECT-TYPE
    SYNTAX          BITS {
                        highAlarmDefThresh(0),
                        highWarnDefThresh(1),
                        lowAlarmDefThresh(2),
                        lowWarnDefThresh(3)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object indicates if the current value of a particular
        threshold in this entry is user configured value or it is 
        a system default value. It also allows user to specify 
        the list of thresholds for this entry which should
        be restored to their system default values.

        The bit 'highAlarmThresh' corresponds to the object
        cOpticalParamHighAlarmThresh.

        The bit 'highWarnThresh' corresponds to the object
        cOpticalParamHighWarningThresh.

        The bit 'lowAlarmThresh' corresponds to the object
        cOpticalParamLowAlarmThresh.

        The bit 'lowWarnThresh' corresponds to the object
        cOpticalParamLowWarningThresh.

        A value of 0 for a bit indicates that corresponding
        object has system default value of threshold.

        A value of 1 for a bit indicates that corresponding
        object has user configured threshold value.

        A user may only change value of each of the bits to zero.

        Setting a bit to 0 will reset the corresponding
        threshold to its default value.

        System will change a bit from 0 to 1 when its corresponding
        threshold is changed by user from its default to any
        other value." 
    ::= { cOpticalMonEntry 19 }
 


-- Notification related objects
cOpticalNotifyEnable OBJECT-TYPE
    SYNTAX          OpticalAlarmSeverityOrZero
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the minimum severity threshold governing
        the generation of cOpticalMonParameterStatus notifications.

        For example, if the value of this object is
        set to 'major', then the agent generates these notifications
        if and only if the severity of the alarm being indicated is
        'major' or 'critical'.

        The values of 'notReported', and 'cleared' do not apply.
        The value of '0' disables the generation of notifications."
    DEFVAL          { 0 } 
    ::= { cOpticalMonGroup 2 }

-- Scalar object(s) for optical monitoring configuration.
cOpticalMonEnable OBJECT-TYPE
    SYNTAX          BITS {
                        all(0)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the types of transceivers for which
        optical monitoring is enabled. 

        A value of 1 for the bit 'all', specifies that optical
        monitoring functionality is enabled for all the types of
        transceivers which are supported by system and have 
        optical monitoring capability."
    ::= { cOpticalMonGroup 3 }

cOpticalMonPollInterval OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "minutes"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the interval in minutes after which
        optical transceiver data will be polled by system
        repeatedly and updated in cOpticalMonTable when one or
        more bits in cOpticalMonEnable is set." 
    ::= { cOpticalMonGroup 4 }
-- cOpticalMonTransceiverTable

cOpticalMonIfTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF COpticalMonIfEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table contains the list of optical interfaces
        populated in cOpticalMonTable."
    ::= { cOpticalMonGroup 5 }

cOpticalMonIfEntry OBJECT-TYPE
    SYNTAX          COpticalMonIfEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry containing the information for a particular optical interface."
    INDEX           { ifIndex } 
    ::= { cOpticalMonIfTable 1 }

COpticalMonIfEntry ::= SEQUENCE {
        cOpticalMonIfTimeInSlot Unsigned32
}

cOpticalMonIfTimeInSlot OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates when this optical transceiver was detected by the
        system."
    ::= { cOpticalMonIfEntry 1 }
 

-- cOpticalPMCurrent Table

cOpticalPMCurrentTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF COpticalPMCurrentEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table contains performance monitoring data for the
        various optical parameters, collected over the current 15
        minute or the current 24 hour interval."
    ::= { cOpticalPMGroup 1 }

cOpticalPMCurrentEntry OBJECT-TYPE
    SYNTAX          COpticalPMCurrentEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry in the cOpticalPMCurrentTable. It contains
        performance monitoring data for a monitored optical
        parameter at an interface, collected over the current 15
        minute or the current 24 hour interval.

        Note that the set of monitored optical parameters may vary
        based on interface type, direction, and monitoring location.

        Examples of interfaces that can have an entry in this table
        include optical transceivers, interfaces before and after
        optical amplifiers, and interfaces before and after optical
        attenuators."
    INDEX           {
                        cOpticalPMCurrentPeriod,
                        ifIndex,
                        cOpticalPMCurrentDirection,
                        cOpticalPMCurrentLocation,
                        cOpticalPMCurrentParamType
                    } 
    ::= { cOpticalPMCurrentTable 1 }

COpticalPMCurrentEntry ::= SEQUENCE {
        cOpticalPMCurrentPeriod      OpticalPMPeriod,
        cOpticalPMCurrentDirection   OpticalIfDirection,
        cOpticalPMCurrentLocation    OpticalIfMonLocation,
        cOpticalPMCurrentParamType   OpticalParameterType,
        cOpticalPMCurrentMaxParam    OpticalParameterValue,
        cOpticalPMCurrentMinParam    OpticalParameterValue,
        cOpticalPMCurrentMeanParam   OpticalParameterValue,
        cOpticalPMCurrentUnavailSecs Integer32
}

cOpticalPMCurrentPeriod OBJECT-TYPE
    SYNTAX          OpticalPMPeriod
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates whether the optical parameter values
        given in this entry are collected over the current 15 minute or
        the current 24 hour interval." 
    ::= { cOpticalPMCurrentEntry 1 }

cOpticalPMCurrentDirection OBJECT-TYPE
    SYNTAX          OpticalIfDirection
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the direction monitored for the optical
        interface, in this entry." 
    ::= { cOpticalPMCurrentEntry 2 }

cOpticalPMCurrentLocation OBJECT-TYPE
    SYNTAX          OpticalIfMonLocation
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates whether the optical characteristics are
        measured before or after adjustment (e.g. optical amplification
        or attenuation), at this interface." 
    ::= { cOpticalPMCurrentEntry 3 }

cOpticalPMCurrentParamType OBJECT-TYPE
    SYNTAX          OpticalParameterType
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored, in this entry." 
    ::= { cOpticalPMCurrentEntry 4 }

cOpticalPMCurrentMaxParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the maximum value measured for the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval." 
    ::= { cOpticalPMCurrentEntry 5 }

cOpticalPMCurrentMinParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the minimum value measured for the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval." 
    ::= { cOpticalPMCurrentEntry 6 }

cOpticalPMCurrentMeanParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the average value of the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval." 
    ::= { cOpticalPMCurrentEntry 7 }

cOpticalPMCurrentUnavailSecs OBJECT-TYPE
    SYNTAX          Integer32 (0..86400 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object is used to indicate the number of seconds,
        in the current 15 minute or the current 24 hour interval, for
        which the optical performance data is not accounted for.

        In the receive direction, the performance data could be
        unavailable during these periods for multiple reasons
        like the interface being administratively down or if there
        is a Loss of Light alarm on the interface. In the transmit
        direction, performance data could be unavailable when
        the laser is shutdown." 
    ::= { cOpticalPMCurrentEntry 8 }
 

-- cOpticalPMInterval Table

cOpticalPMIntervalTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF COpticalPMIntervalEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table stores performance monitoring data for the
        various optical parameters, collected over previous
        intervals.

        This table can have entries for one complete 24 hour
        interval and up to 96 complete 15 minute
        intervals. A system is required to store at least
        4 completed 15 minute intervals. The number of valid
        15 minute intervals in this table is indicated by the
        cOpticalMon15MinValidIntervals object and the number of
        valid 24 hour intervals is indicated by the
        cOpticalMon24HrValidIntervals object."
    ::= { cOpticalPMGroup 2 }

cOpticalPMIntervalEntry OBJECT-TYPE
    SYNTAX          COpticalPMIntervalEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry in the cOpticalPMIntervalTable. It contains
        performance monitoring data for an optical parameter,
        collected over a previous interval.

        Note that the set of monitored optical parameters may vary
        based on interface type, direction, and monitoring location.

        Examples of interfaces that can have an entry in this table
        include optical transceivers, interfaces before and after
        optical amplifiers, and interfaces before and after optical
        attenuators."
    INDEX           {
                        cOpticalPMIntervalPeriod,
                        cOpticalPMIntervalNumber,
                        ifIndex,
                        cOpticalPMIntervalDirection,
                        cOpticalPMIntervalLocation,
                        cOpticalPMIntervalParamType
                    } 
    ::= { cOpticalPMIntervalTable 1 }

COpticalPMIntervalEntry ::= SEQUENCE {
        cOpticalPMIntervalPeriod      OpticalPMPeriod,
        cOpticalPMIntervalNumber      Integer32,
        cOpticalPMIntervalDirection   OpticalIfDirection,
        cOpticalPMIntervalLocation    OpticalIfMonLocation,
        cOpticalPMIntervalParamType   OpticalParameterType,
        cOpticalPMIntervalMaxParam    OpticalParameterValue,
        cOpticalPMIntervalMinParam    OpticalParameterValue,
        cOpticalPMIntervalMeanParam   OpticalParameterValue,
        cOpticalPMIntervalUnavailSecs Integer32
}

cOpticalPMIntervalPeriod OBJECT-TYPE
    SYNTAX          OpticalPMPeriod
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates whether the optical parameter values,
        given in this entry, are collected over a period of 15 minutes
        or 24 hours." 
    ::= { cOpticalPMIntervalEntry 1 }

cOpticalPMIntervalNumber OBJECT-TYPE
    SYNTAX          Integer32 (1..96 )
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A number between 1 and 96, which identifies the
        interval for which the set of optical parameter values is
        available. The interval identified by 1 is the most recently
        completed 15 minute or 24 hour interval, and the interval
        identified by N is the interval immediately preceding the one
        identified by N-1." 
    ::= { cOpticalPMIntervalEntry 2 }

cOpticalPMIntervalDirection OBJECT-TYPE
    SYNTAX          OpticalIfDirection
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the direction monitored for the optical
        interface, in this entry." 
    ::= { cOpticalPMIntervalEntry 3 }

cOpticalPMIntervalLocation OBJECT-TYPE
    SYNTAX          OpticalIfMonLocation
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates whether the optical characteristics
        are measured before or after adjustment (e.g.
        optical amplification or attenuation), at this interface." 
    ::= { cOpticalPMIntervalEntry 4 }

cOpticalPMIntervalParamType OBJECT-TYPE
    SYNTAX          OpticalParameterType
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored, in this entry." 
    ::= { cOpticalPMIntervalEntry 5 }

cOpticalPMIntervalMaxParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the maximum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::= { cOpticalPMIntervalEntry 6 }

cOpticalPMIntervalMinParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the minimum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::= { cOpticalPMIntervalEntry 7 }

cOpticalPMIntervalMeanParam OBJECT-TYPE
    SYNTAX          OpticalParameterValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object gives the average value of the measured optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::= { cOpticalPMIntervalEntry 8 }

cOpticalPMIntervalUnavailSecs OBJECT-TYPE
    SYNTAX          Integer32 (0..86400 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object is used to indicate the number of seconds,
        in the particular 15 minute or 24 hour interval, for which the
        optical performance data is not accounted for.

        In the receive direction, the performance data could be
        unavailable during these periods for multiple reasons
        like the interface being administratively down or if there
        is a Loss of Light alarm on the interface. In the transmit
        direction, performance data could be unavailable when
        the laser is shutdown." 
    ::= { cOpticalPMIntervalEntry 9 }
 

-- Notifications
cOpticalMonitorMIBNotifications  OBJECT IDENTIFIER
    ::= { ciscoOpticalMonitorMIB 2 }

cOpticalMonNotificationPrefix  OBJECT IDENTIFIER
    ::= { cOpticalMonitorMIBNotifications 0 }



cOpticalMonParameterStatus NOTIFICATION-TYPE
    OBJECTS         {
                        cOpticalParameterValue,
                        cOpticalParamAlarmStatus,
                        cOpticalParamAlarmCurMaxThresh,
                        cOpticalParamAlarmCurMaxSev,
                        cOpticalParamAlarmLastChange
                    }
    STATUS          current
    DESCRIPTION
        "This notification is sent when any threshold related to an
        optical parameter is exceeded or cleared on an interface.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the cOpticalNotifyEnable object,
          or
        - if the severity of the threshold as specified by
          the cOpticalParamHighWarningSev or
          cOpticalParamLowWarningSev object is 'notReported'.
        "
   ::= { cOpticalMonNotificationPrefix 1 }
-- MIB Conformance Statements
cOpticalMonitorMIBConformance  OBJECT IDENTIFIER
    ::= { ciscoOpticalMonitorMIB 3 }

cOpticalMonitorMIBCompliances  OBJECT IDENTIFIER
    ::= { cOpticalMonitorMIBConformance 1 }

cOpticalMonitorMIBGroups  OBJECT IDENTIFIER
    ::= { cOpticalMonitorMIBConformance 2 }


cOpticalMonitorMIBCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "The compliance statement for network elements that
        monitor optical characteristics and set thresholds on the
        optical interfaces in a network element."
    MODULE          -- this module
    MANDATORY-GROUPS { cOpticalMIBMonGroup }

    GROUP           cOpticalMIBThresholdGroup
    DESCRIPTION
        "This group is required for network elements that support
        thresholds on optical parameters."

    GROUP           cOpticalMIBSeverityGroup
    DESCRIPTION
        "This group is required for network elements that support
        severities for thresholds on optical parameters."

    GROUP           cOpticalMIBPMGroup
    DESCRIPTION
        "This group is required for network elements that
        support collection of optical performance monitoring
        data for 15 minute or 24 hour intervals."

    GROUP           cOpticalMIBNotifyEnableGroup
    DESCRIPTION
        "This group is required for network elements that
        support the cOpticalMIBNotifGroup."

    GROUP           cOpticalMIBNotifGroup
    DESCRIPTION
        "This group is required for network elements that
        generate notifications when a threshold is exceeded or
        cleared on an interface."

    OBJECT          cOpticalParamHighAlarmThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighWarningThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowAlarmThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowWarningThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighAlarmSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighWarningSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowAlarmSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowWarningSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."
    ::= { cOpticalMonitorMIBCompliances 1 }

cOpticalMonitorMIBComplianceRev MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "The compliance statement for network elements that
        monitor optical characteristics and set thresholds on the
        optical interfaces in a network element."
    MODULE          -- this module
    MANDATORY-GROUPS { cOpticalMIBMonGroup }

    GROUP           cOpticalMIBThresholdGroup
    DESCRIPTION
        "This group is required for network elements that support
        thresholds on optical parameters."

    GROUP           cOpticalMIBSeverityGroup
    DESCRIPTION
        "This group is required for network elements that support
        severities for thresholds on optical parameters."

    GROUP           cOpticalMIBPMGroup
    DESCRIPTION
        "This group is required for network elements that
        support collection of optical performance monitoring
        data for 15 minute or 24 hour intervals."

    GROUP           cOpticalMonIfTimeGroup
    DESCRIPTION
        "This group is required for network elements that maintain
        time related information for optical transceivers."

    GROUP           cOpticalMIBNotifyEnableGroup
    DESCRIPTION
        "This group is required for network elements that
        support the cOpticalMIBNotifGroup."

    GROUP           cOpticalMIBNotifGroup
    DESCRIPTION
        "This group is required for network elements that
        generate notifications when a threshold is exceeded or
        cleared on an interface."

    GROUP           cOpticalMIBEnableConfigGroup
    DESCRIPTION
        "This group is required for network elements that
        are capable of enabling/disabling optical monitoring 
        functionality."

    GROUP           cOpticalMIBIntervalConfigGroup
    DESCRIPTION
        "This group is mandatory for network elements that
         support optical monitoring polling interval
         configuration."

    GROUP           cOpticalMonThreshSourceGroup
    DESCRIPTION
        "This group is mandatory for the network elements that
         support restoring the optical monitoring threshold
         to the default value."

    OBJECT          cOpticalParamHighAlarmThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighWarningThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowAlarmThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowWarningThresh
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighAlarmSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamHighWarningSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowAlarmSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."

    OBJECT          cOpticalParamLowWarningSev
    MIN-ACCESS      read-only
    DESCRIPTION     "Write access is not required."
    ::= { cOpticalMonitorMIBCompliances 2 }

-- Units of Conformance
cOpticalMIBMonGroup OBJECT-GROUP
    OBJECTS         { cOpticalParameterValue }
    STATUS          current
    DESCRIPTION
        "A mandatory object that provides monitoring of optical
        characteristics."
    ::= { cOpticalMonitorMIBGroups 1 }

cOpticalMIBThresholdGroup OBJECT-GROUP
    OBJECTS         {
                        cOpticalParamHighAlarmThresh,
                        cOpticalParamHighWarningThresh,
                        cOpticalParamLowAlarmThresh,
                        cOpticalParamLowWarningThresh,
                        cOpticalParamAlarmStatus,
                        cOpticalParamAlarmCurMaxThresh,
                        cOpticalParamAlarmLastChange
                    }
    STATUS          current
    DESCRIPTION
        "A collection of objects that support thresholds on optical
        parameters and provide status information when the thresholds
        are exceeded or cleared."
    ::= { cOpticalMonitorMIBGroups 2 }

cOpticalMIBSeverityGroup OBJECT-GROUP
    OBJECTS         {
                        cOpticalParamHighAlarmSev,
                        cOpticalParamHighWarningSev,
                        cOpticalParamLowAlarmSev,
                        cOpticalParamLowWarningSev,
                        cOpticalParamAlarmCurMaxSev
                    }
    STATUS          current
    DESCRIPTION
        "A collection of objects that support severities for thresholds
        on optical parameters."
    ::= { cOpticalMonitorMIBGroups 3 }

cOpticalMIBPMGroup OBJECT-GROUP
    OBJECTS         {
                        cOpticalMon15MinValidIntervals,
                        cOpticalMon24HrValidIntervals,
                        cOpticalPMCurrentMaxParam,
                        cOpticalPMCurrentMinParam,
                        cOpticalPMCurrentMeanParam,
                        cOpticalPMCurrentUnavailSecs,
                        cOpticalPMIntervalMaxParam,
                        cOpticalPMIntervalMinParam,
                        cOpticalPMIntervalMeanParam,
                        cOpticalPMIntervalUnavailSecs
                    }
    STATUS          current
    DESCRIPTION
        "A collection of objects that provide optical performance
        monitoring data for 15 minute and 24 hour intervals."
    ::= { cOpticalMonitorMIBGroups 4 }

cOpticalMIBNotifyEnableGroup OBJECT-GROUP
    OBJECTS         { cOpticalNotifyEnable }
    STATUS          current
    DESCRIPTION
        "An object to control the generation of notifications."
    ::= { cOpticalMonitorMIBGroups 5 }

cOpticalMIBNotifGroup NOTIFICATION-GROUP
   NOTIFICATIONS    { cOpticalMonParameterStatus }
    STATUS          current
    DESCRIPTION
        "A notification generated when a threshold on an optical
        parameter is exceeded or cleared."
    ::= { cOpticalMonitorMIBGroups 6 }

cOpticalMonIfTimeGroup OBJECT-GROUP
    OBJECTS         { cOpticalMonIfTimeInSlot }
    STATUS          current
    DESCRIPTION
        "A collection of object(s) that provide time related information
        for transceivers in the system."
    ::= { cOpticalMonitorMIBGroups 7 }

cOpticalMIBEnableConfigGroup OBJECT-GROUP
    OBJECTS         { cOpticalMonEnable }
    STATUS          current
    DESCRIPTION
        "A collection of object(s) to enable/disable optical
        monitoring."
    ::= { cOpticalMonitorMIBGroups 8 }

cOpticalMIBIntervalConfigGroup OBJECT-GROUP
    OBJECTS         { cOpticalMonPollInterval }
    STATUS          current
    DESCRIPTION
        "A collection of object(s) to specify polling interval for
        monitoring optical transceivers."
    ::= { cOpticalMonitorMIBGroups 9 }

cOpticalMonThreshSourceGroup OBJECT-GROUP
    OBJECTS         { cOpticalParamThreshSource }
    STATUS          current
    DESCRIPTION
        "A collection of object(s) to restore a given threshold
        to its default value."
    ::= { cOpticalMonitorMIBGroups 10 }

END